DILUTION COLUMN
Concentrated chemical solutions as received from production of bulk shipment often
require dilution prior to their process use. For example, sodium hydroxide received at 30%
(membrane cell liquor) to 50% (bulk shipment) must be diluted (e.g. to 5% to 10%). This
can be done automatically in the Dilution Column.
The Dilution Column is delivered as a module with all piping and instrumentation required
ready for operation upon installation. Piping connections are provided for strong
solution,
dilution water and the diluted product stream. Dilution Columns are constructed of
materials appropriate to the solutions being diluted, e.g. carbon steel (for caustic
soda),
stainless steels, titanium and synthetics.
FEATURES
Dilution Column
Strong solution flow control to maintain dilute concentration
(density) set point
Water flow control to meet dilute solution demand (level)
Manual block valves, check valves, piping
Skid mounted ready for installation
OPTIONS
Electronic (digital or analog) or pneumatic instrumentation.
Conductivity or temperature differential dilute solution
concentration control.
Reduced height for limited headroom clearance.
Alternate materials of construction.
Individual components.
Complete system supply including:
Storage Tanks,
Pumps,
Piping and Valves,
Instrumentation and controls, and Electrical.


Dilution Column Modules and Components
SR-1029-A